ComPAC Family50 to 600 WattDC-DC SwitchersApplication NotesFunctional and Mechanical LayoutInstallation and Operation GuidelinesProduct DescriptionThe
Application Notes2The Master Disable input is optically isolated and incorporates a reverse polarityprotection diode. Apply a current of up to 20 mA t
3+ VOUTTo Load— VOUTR110KR2+ OUT+ SENSETRIM— SENSE— OUTResistor Values for Trimming Standard Output VoltagesNominal Output Voltage 5 V 12 V 15 V 24 V
Functional and Mechanical Layout4Drawing: P.N. 11926LC-SeriesSingle output50-200 WattsMC-SeriesSingle output100-400 WattsNC-SeriesSingle output300-600
5NC-Series QC-Series RC-SeriesMC-Series PC-SeriesLC-SeriesOutputs2.76(70,1)OUTPUT 1 OUTPUT 2OUTPUT 1OUTPUT 1 OUTPUT 2 OUTPUT 36 PLACES#10-32 STUD2 PLA
Installation and Operation GuidelinesInput Line Fusing. The ComPAC must be fused externally. The table below lists the fuseratings for one-, two-, and
Metal TerminalDrawing: P.N. 10894 #1Terminal and Terminal RecommendedProduct Model Style Stud Size Torque–Output, +OutputLC-, PC-, & PCB 8-32 UNC
Sicherheits-Vorschriften8Absicherung am Eingang. Das ComPAC muß mit einer externenSicherung am Eingang versehen werden. Die entsprechendenSicherungswe