vicorpower.com Applications Engineering: 800 927.9474 Page 4
Output Power De-rating Curve
The MicroPAC is designed to operate from a single electrical phase; as such it can be operated directly
from a normal wall outlet socket. These sockets are normally rated for 12 A continuous current draw
and 15 A peak current draw. With this in mind it is necessary to institute a power de-rating curve to
maintain the operational range of the MicroPAC within these boundaries.
MicroPAC to MicroPAC Current Sharing
The MicroPAC power supplys with the same output voltages can be placed in parallel arrays by
connecting the output positive (+) and return (-) rails to the respective positive and return rails of the
next MicroPAC. If individual MicroPAC's are configured in an array it is necessary to make sure all
MicroPAC are powered up at the same time. Pin 2 (0V +5V return) of the customer interface connector
should be daisy chained together on each MicroPAC in the array. The GSD signal Pin 8 should also
be daisy chained together and be used to turn on all outputs at the same time. The current sharing
is achieved by using the droop sharing method and produces in the order of 5 –10% Current sharing
accuracy. (Contact factory for details).
It is important to note that following good cable routing and symmetry is critical for good current
sharing and load balancing.
80 90 100 110 120 130 140 150
160 170 180 190 200 210 220 230
850
895
940
985
1030
1075
1120
1165
1210
1255
1300
Output Power (Watts)
Output Power De-rating Curve
vs. AC Input voltage
AC Input (Vrms)
Output Power (W)
Figure 2:
Output Power De-rating Curve
vs.
AC Input Voltage